1.
JPMI-Journal of Postgraduate Medical Institute. 2016; 30 (1): 41-47
in English | IMEMR | ID: emr-178994

ABSTRACT

Objective: To compare the percutaneous radiologically guided gastrostomy [PeRG] tubes of wide caliber with narrow caliber tubes


Methodology: This retrospective study was performed on 36 patients who were referred to Radiology department for PeRG tube placement between 2008 till 2012. Comparison of wide caliber gastrostomy tubes [18-24 Fr] was done with narrow caliber tubes [14 Fr] considering procedure success rate, procedure related complications and catheter related minor and major complications


Results: Out of 36 patients, 18 patients were present in each group. Mean age of patients was 53.944 +/- 19.380. Procedure success rate was 100% in both groups and procedure related immediate complications were none in either groups. Peri-catheter leakage was observed in 1 patient in each group. Tube occlusion was present in 2 patients in narrow caliber group. Two patients had severe pain in wide caliber group and also 3 patients had wound infection in this group


Conclusion: Regardless of the type of radiologic catheter placed, PeRG can be considered as safe and highly successful procedure. Use of a 24 Fr gastrostomy tubes may show promising results if placed under radiological guidance with comparable technical success and complication rates to other caliber tubes


Subject(s)
Humans , Male , Female , Aged , Middle Aged , Technology, Radiologic , Retrospective Studies , Catheters , Administration, Cutaneous
2.
JPMI-Journal of Postgraduate Medical Institute. 2015; 29 (4): 231-236
in English | IMEMR | ID: emr-179779

ABSTRACT

Objective: to compare bone marrow biopsy needle [BMBN] with bone biopsy needle [BBN] in CT guided core biopsies considering size of core, diagnostic yield and cost of needles


Methodology: retrospective study was done on 50 out of 68 patients referred to Interventional Radiology department for CT guided bone biopsy from 2008 till 2013. Grading of specimen length was done as small, medium and large. Diagnostic yield was determined on basis of clinical, imaging and histopathology data. Local cost of both needle types was determined. Comparison was made and statistical analysis was performed


Results: biopsy was performed by BBN in 16 patients and by BMBN in 34 patients. Overall diagnostic yield of bone biopsies was 82% [41 of 50 biopsies]. Diagnostic yield with BMBN was 85% and with BBN was 75%. Overall longer specimen length was obtained using BMBN. Statistically, there was no significant difference between them in diagnostic yield and specimen length; however, BMBN costs almost one half than BBN


Conclusion: diagnostic yield and sample length using bone marrow biopsy needle proved to be equivalent to bone biopsy needle. Bone marrow biopsy needle has an added benefit of being low in cost. Despite being a non-coaxial technique these needles can achieve diagnostic yield comparable to that of coaxial techniques as reported in past literature